Delete existing table 6 8 3 in its entirety and replace with tables 6 8 3a and 6 8 3b addendum bi to 90 1 2007 table 6 8 3 minimum pipe insulation thicknessesa fluid design operat ing temp.
Chilled water pipe insulation thickness table.
To avoid heat loss and reduced system efficiency pipe work in heating systems should always be insulated.
Pipe unions in heating systems steam steam con densate and hot water.
Table 6 8 3a minimum pipe insulation thickness.
Pipe insulation fits around hot water pipes and reduces heat loss to save energy and lower energy costs.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a class i or class ii vapor retarder.
View more view all jump to.
When piping and equipment.
Water pipe insulation the following piping shall be insulated to levels shown in section 6 table 6 8 3.
D recirculating system piping including the supply and return piping of a circulating tank type water heater.
Wall thickness insulation 3 8 in 46 1 2 in 124 3 4 in 96 1 in 219 1 1 2 in 58 2 in 50 insulation length.
2 0 role of pipe insulation for chilled water systems 33 f to 60 f 0 5 c to 15 6 c pipe insulation for chilled water systems is specified and installed primarily for process control condensation control and energy conservation.
Section 120 3 requirements for pipe insulation.
Pre slit polyethylene pipe insulation.
In general there are no insulation thickness requirements for residential domestic hot water pipes but we find that 1 thickness will greatly reduce the loss of heat transmission.
Very hot systems like hot water and steam systems should also be insulated to avoid potential personal injuries.
The table below indicates recommended insulation thickness.
For below ambient service by contrast the new pipe insulation thicknesses are not particularly noteworthy.
Insulating chilled water systems requires special attention.
This calculation determines the ideal thickness of water piping insulation for efficiently and economically preventing a heat transfer from outside to inside and keeping the water transported within cool it does not determine the thickness of insulation designed to keep condensate or other fluids from losing heat.
For example 1 in.
6 7 bs5422 table table referencepage no 6 minimum insulation thickness for chilled and cold water steel pipes to control condensation on a high emissivity outer surface 0 9 with an ambient temperature of 25 c and a relative humidity of 80.
Use of 1 1 2 or 2 thick fiberglass pipe insulation will most likely not be cost effective on domestic hot water unless the size of the pipe is greater than 3 ips.
T insulation thickness from table 120 3 a inches.